Precautions for installing water softener equipment

2022-09-05 16:59:14

       As industrial production expanded and water pollution became increasingly severe, people devised various methods to ensure the safety and hygiene of drinking water, leading to the widespread use of water purification equipment. The purified water system uses multi-stage purification, enabling direct tap water supply. The softening water equipment mainly removes calcium and magnesium ions from the water. When the influent water is deep well water or the source is very hard, the purpose of using softened water is to remove the calcium and magnesium ion content from the water, thereby reducing the calcium and magnesium ions in the water. Water softening equipment cannot reduce the total salt content in the water during the process of softening. It is widely used in hot water boiler systems, heat exchange systems, industrial cooling systems, central air conditioning systems, and other water-consuming equipment systems. Next, let me introduce softened waterEquipment installationPrecautions at the time.


       1. This installation must be placed indoors to prevent freezing and sun exposure, and must be protected from impacts during movement.


  2. During installation, leave a 0.5-meter clearance around the area for maintenance.


  3. The inlet water pressure should be between 0.2-0.6MPa; if unsatisfactory, additional pressure reduction methods can be added.


  4. Users should provide their own softening water tank, with volume determined according to usage to meet water requirements. The soft water tank should have anti-corrosion measures to prevent further contamination.


  5. No installation foundation is required; it can be installed at the foundation level, requiring a sewage drainage channel near the ground.


  6. Maintain the salt solution to reach saturation concentration; solid salt should be higher than the salt surface level.


  7. After installation, the pipes should be flushed to prevent impurities from causing blockages and resin contamination.